Current Issue : October - December Volume : 2011 Issue Number : 1 Articles : 5 Articles
The need for high-quality out-of-hospital healthcare is a known socioeconomic problem. Exploiting ICT's evolution, ad-hoc telemedicine solutions have been proposed in the past. Integrating such ad-hoc solutions in order to cost-effectively support the entire healthcare cycle is still a research challenge. In order to handle the heterogeneity of relevant information and to overcome the fragmentation of out-of-hospital instrumentation in person-centric healthcare systems, a shared and open source interoperability component can be adopted, which is ontology driven and based on the semantic web data model. The feasibility and the advantages of the proposed approach are demonstrated by presenting the use case of real-time monitoring of patients' health and their environmental context....
The latest population-based studies in the medical literature worldwide indicate that acute myocardial infarction (AMI) patients still experience prolonged delay to be rescued, which often results in morbidity and mortality. This paper reports from a technological standpoint a teleconsultation and monitoring system named AToMS. This system addresses the problem of prehospital delivery of thrombolysis to AMI patients by enabling the remote interaction of the paramedics and a cardiologist available at a Coronary Care Unit (CCU). Such interaction allows the diagnosis of the patient eligibility to the immediate application of thrombolysis, which is meant to reduce the delay between the onset of symptoms and the eventual application of proper treatment. Such delay reduction is meant to increase the AMI patient's chances of survival and decrease the risks of postinfarction sequels. The teleconsultation is held with the support of wireless and mobile technologies, which also allows the cardiologist to monitor the patient while he/she is being taken to the nearest CCU. All exchanged messages among paramedics and cardiologists are recorded to render an auditable system. AToMS has been deployed in a first stage in the city of Rio de Janeiro, where the medical team involved in the project has conducted commissioned tests....
With significant declines in cardiovascular disease (CVD) mortality, attention has shifted to patient management. Programs designed to manage CVD require the involvement of health professionals for comanagement and patients' self-management. However, these programs are commonly limited to large urban centers, resulting in limited access for rural patients. The use of telehealth potentially overcomes geographical barriers and can improve access to care for patients. The current research explores how an Internet-based platform might facilitate collaboration among healthcare providers comanaging patients and enhance behavioural change in patients. Forty-eight participants were interviewed including: (a) patients (?? = 1 2), (b) physicians (?? = 1 1), (c) nurses (?? = 1 3),and (d) allied health professionals (?? = 1 0\r\n). The results were organized and analyzed in three central themes: (1) role of technology for CVD management, (2) challenges to technology adoption, and (3) incentives for technology adoption. Health care providers and patients supported future implementation of Internet-based technology support for CVD management....
The aim of this paper was to evaluate whether primary health care staff's referral of patients to perform an electronic screening and brief intervention (e-SBI) for alcohol use had a greater impact on change in alcohol consumption after 3 month, compared to patients who performed the test on their own initiative. Staff-referred responders reported reduced weekly alcohol consumption with an average decrease of 8.4 grams. In contrast, self-referred responders reported an average increase in weekly alcohol consumption of 2.4 grams. Staff-referred responders reported a 49% reduction of average number of heavy episodic drinking (HED) occasions per month. The corresponding reduction for self-referred responders was 62%. The differences between staff- and self-referred patient groups in the number who moved from risky drinking to nonrisky drinking at the followup were not statistically significant. Our results indicate that standalone computers with touchscreens that provide e-SBIs for risky drinking have the same effect on drinking behaviour in both staff-referred patients and self-referred patients....
Recent technical development focused on real-time heart rate monitoring instead of postexercise evaluation of recorded data. There are several systems on the market that allow direct and real-time monitoring of several individuals at the same time. The present study compared the systems of Polar, Acentas, Activio, and Suunto in a field test with twelve subjects regarding failure quota, operating distance, and ECG validity. Moreover, the installation and use of software and hardware were evaluated with a quality rating system. Chest belts were evaluated with a questionnaire, too. Overall the system of Acentas reached the best mark of all systems, but detailed results showed that every system has its advantages and disadvantages depending on using purpose, location, and weather. So this evaluation cannot recommend a single system but rather shows strength and weakness of all systems and additionally can be used for further system improvements....